Open the power button on the right control panel to power on;
1. Start manually; Press the manual button (palm print) once, and then press the green confirm button (start) to start the engine. After idling for 20 seconds, the high speed will be automatically adjusted, waiting for the engine to run. After normal operation, turn on the power and gradually increase the load to avoid sudden load.
2. Start automatically; Press the (Auto) auto key; Automatically start the engine, no manual operation, can be automatically powered on. (If the mains voltage is normal, the generator cannot start).
3. If the unit works normally (frequency :50Hz, voltage :380-410v, engine speed :1500), turn off the switch between the generator and the negative switch, and then gradually increase the load and send power to the outside world. Don't suddenly overload.
Generator Operation
1. After no-load planting is stable, gradually increase the load to avoid sudden load planting;
2. Pay attention to the following matters during operation: always pay attention to the change of water temperature, frequency, voltage and oil pressure. If abnormal, stop to check fuel, oil and coolant storage condition. At the same time, check whether the diesel engine has oil leakage, water leakage, air leakage and other abnormal phenomena, observe whether the diesel exhaust smoke color is abnormal (normal smoke color is light cyan, if it is dark blue, it is dark black), should stop for inspection. Water, oil, metal or other foreign matter shall not enter the motor. Motor three-phase voltage should be balanced;
3. If there is abnormal noise during operation, stop the machine in time for inspection and solution;
4. There should be detailed records during operation, including environmental state parameters, oil engine operating parameters, start time, stop time, stop reason, failure reason, etc.;
During the operation of the low-power generator set, the fuel should be kept sufficient. During the operation, the fuel should not be cut off.
Post time: Jul-07-2023